Journal of Electron Microscopy 47(5): 535-537 (1998)
© 1998 Oxford University Press
A simple flat embedding method for the correlative light and electron microscopic immunocytochemistry
Department of Anatomy, Yokohama City University, School of Medicine Fukuura 3-9, Kanazawa-ku, Yokohama 236-0004, Japan
*To whom correspondence should be addressed. E-mail: hsawada{at}yellow.med.yokohama-cu.ac.jp
For correlative light and electron microscopic immunocytochemistry, a simple method for flat embedding of cryostat sections in Epon was devised. In the present technique tissue sections were attached to widely used silane-coated slides, processed, and embedded in Epon beneath non-adhesive transparent plastic films. The Epon block can be easily removed from slides by heating. This method simultaneously offers transparency and thinness of the embedded blocks, absolute flatness of the sections, and easy removal of Epon from embedding molds.
Keywords embedding, Aclar film, OHP film, Epon, immunocytochemistry, immunoelectron microscopy
Received 24 February 1998, accepted 30 June 1998
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
H. Sawada and M. Esaki A Practical Technique to Postfix Nanogold-immunolabeled Specimens with Osmium and to Embed Them in Epon for Electron Microscopy J. Histochem. Cytochem., April 1, 2000; 48(4): 493 - 498. [Abstract] [Full Text] |
||||