Journal of Electron Microscopy 48(3): 235-244 (1999)
© 1999 Oxford University Press

Optimization of TEm specimen preparation by double-sided ion beam thinning under low angles

A. Strecker, J. Mayer*, B. Baretzky, W. Eigenthaler, Th. Gemming, R. Schweinfest and M. Rühle

Max-Palnck-Institut für Metallforshung Seestrasse 92, D-70174 Stuttgrat, Germany

*To whom correspondence should be sent.E-mail: jmayer{at}mf.mpi-stuttgart.mpg.de

We have developed special specimen holders for double-sided low angle ion beam thinning and have systematically studied possible improvements of the resulting TEM specimens with respect to surface roughness, radiation-induced damage and contamination. The specimen holders are entirely made from graphite and were built for two different ion beam thinners. The design makes it possible to work at angles of incidence of 6° and lower and to precisely position the centre of rotation. The resulting specimen geometry was characterized with respect to a number of critical parameters. The surface topography was measured with atomic force microscopy, defect-induced localized strain was revealed by HRTEM and the thicknesses of contamination layers, carbon coating and amorphous oxide layers were quantitatively determined by electron spectroscopic imaging in an energy filtering TEM. It was found that the surface roughness not only decreases with decreasing angle of incidence, but also when the ion energy is lowered. In the lowangle regime, the thinning mechanism is based on the formation and propagation of ledges. Simultaneous ion bombardment from both sides has been found to be one of the most critical parameters.

Keywords     TEM specimen preparation, ion beam thinning

Received     12 November 1998, accepted 15 February 1998


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.