Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Kabius, B.
Right arrow Articles by Rose, H.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Kabius, B.
Right arrow Articles by Rose, H.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Journal of Electron Microscopy 51:S51-S58 (2002)
© 2002 Oxford University Press


Full-length paper

First application of a spherical-aberration corrected transmission electron microscope in materials science

Bernd Kabius1,*, Max Haider2, Stefan Uhlemann2, Eugen Schwan2, Knut Urban3 and Harald Rose4

1Material Science Department, Argonne National Laboratory, Argonne, IL 60439,
2CEOS GmbH, Engler Strasse, D-69126 Heidelberg,
3Institut für Festkörperphysik, Forschungszentrum Jülich, D-52425 Jülich and
4Institut für Angewandte Physik, Hochschulstrasse 6, D-64289 Darmstadt, Germany

To whom correspondence should be addressed. E-mail: kabius{at}anl.gov

One of the most challenging tasks for high-resolution electron microscopy is the investigation of the atomic structure of defects, interfaces, and grain boundaries. In particular, the application of thin films in electronic devices requires detailed knowledge of the microstructure, which can influence the electronic and optical properties. These tasks require a point resolution down to about 0.1 nm because this enables structure imaging for many semiconductors and metals. The resolution of transmission electron microscopes is limited, besides other parameters, by the spherical aberration coefficient Cs of the objective lens and the wavelength {lambda} of the electrons. Commercial medium-voltage microscopes up to 400 kV offer only a point resolution of 0.16 nm due to the high spherical-aberration constant Cs of the electromagnetic objective lens. Controlling the value of Cs by a corrector lens system can offer the required resolution even at an acceleration voltage of 200 kV. Recently, a lens system for Cs-correction, based on hexapole lenses, has been developed at the European Molecular Biology Laboratory in Heidelberg and incorporated in a commercial 200 kV instrument equipped with a field emission gun (Haider M, Rose H, Uhlemann H, Schwan E, Kabius B and Urban K Nature 392: 768 (1998) [1]). This system allows the Cs-value to be set between +2.0 mm and -0.05 mm. For the present investigation, we have adjusted a Cs-value of 50 µm in order to achieve optimum phase contrast, which improved the point resolution to 0.14 nm. Structure imaging can be performed down to atomic distances of 0.14 nm. A further unique advantage of Cs correction is the reduction of contrast delocalization, which is a major obstacle in the interpretation of images of defects and interfaces. The influence of Cs on contrast delocalization is demonstrated for a Si/CoSi2 interface. The unique combination of a low acceleration voltage and aberration-free imaging down to the information limit offers new prospects for the interpretation of non-periodic structures as defects and interfaces in crystalline materials.

Keywords     TEM, aberrations, Cs correction, contrast delocalization, interfaces, silicides


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.