Skip Navigation


Journal of Electron Microscopy Advance Access originally published online on December 24, 2008
Journal of Electron Microscopy 2009 58(3):175-183; doi:10.1093/jmicro/dfn028
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Supplementary Data
Right arrow All Versions of this Article:
58/3/175    most recent
dfn028v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Jarausch, K.
Right arrow Articles by Leonard, D. N.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jarausch, K.
Right arrow Articles by Leonard, D. N.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2008. Published by Oxford University Press on behalf of Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oxfordjournals.org

This article appears in the following Journal of Electron Microscopy issue: Special number: Advanced electron microscopy in materials physics [View the issue table of contents]

Three-dimensional electron microscopy of individual nanoparticles

Konrad Jarausch1,* and Donovan N. Leonard2

1 Hitachi High-Technologies Corp., 5100 Franklin Dr, Pleasanton, CA 94588, USA
2 Department of Physics and Astronomy, Appalachian State University, Boone, NC 28608, USA

* To whom correspondence should be addressed. E-mail: konradjarausch{at}yahoo.com

The characterization of nanomaterials with complex three-dimensional (3D) geometries is required to further research and enable the continuing development of nanotechnology. In this manuscript, we report a protocol which combines focused ion beam (FIB) milling, thin film deposition and solution chemistry to optimize a rotation holder for 3D structural and chemical analysis of nanoparticles. This protocol is used to customize the geometry, surface and chemistry of a scanning transmission electron microscope (STEM) or transmission electron microscope (TEM) rotation holder for the nanoparticle system of interest. To illustrate this concept, rotation holder stubs were optimized to facilitate the 3D STEM imaging and analysis of core-shell nanoparticles used for DNA detection. Using this approach, it was possible to characterize the morphology, optoelectronic properties and chemical composition of individual core-shell nanoparticles in 3D. STEM images were captured at regular angular intervals over a complete 360° rotation to eliminate missing wedge artifacts. Electron energy-loss spectroscopy (EELS) spectrum images were acquired intermittently for comparative chemical analysis. This approach allows the 3D STEM/TEM analysis to be performed with the nanoparticle of interest cantilevered over vacuum to minimize substrate effects. Standard tomography techniques were used to reconstruct the 3D structure of the individual nanoparticles from the STEM HAADF rotation series. EELS spectrum imaging was used to determine the local material properties such as composition, band-gap and plasmon energy. The nanoparticle analysis protocol reported here can easily be adapted to facilitate 3D TEM/STEM analysis of other nanomaterial systems.

Keywords     nanoparticle, tomography, tilt series, missing wedge

Received     31 August 2008, accepted 1 December 2008


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.