Skip Navigation



Journal of Electron Microscopy Advance Access published online on August 2, 2005

Journal of Electron Microscopy, doi:10.1093/jmicro/dfi024
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
54/3/191    most recent
dfi024v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Ishizuka, K.
Right arrow Articles by Allman, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ishizuka, K.
Right arrow Articles by Allman, B.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2005. Published by Oxford University Press on behalf of Japanese Society of Microscopy. All rights reserved. For Permissions, please email: journals.permissions@oupjournals.org
Received January 25, 2005
Accepted March 8, 2005

Full-length paper

Phase measurement of atomic resolution image using transport of intensity equation

Kazuo Ishizuka 1* and Brendan Allman 2

1 HREM Research Inc., Matsukazedai, Saitama 355-0055, Japan
2 IATIA Ltd., Box Hill Nth, Vic. 3129, Australia

* To whom correspondence should be addressed.
Kazuo Ishizuka, E-mail: ishizuka{at}hremresearch.com


   Abstract

Since the Transport Intensity Equation (TIE) has been applied to electron microscopy only recently, there are controversial discussions in the literature regarding the theoretical concepts underlying the equation and the practical techniques to solve the equation. In this report we explored some of the issues regarding the TIE, especially bearing electron microscopy in mind, and clarified that: (i) the TIE for electrons exactly corresponds to the Schrödinger equation for high-energy electrons in free space, and thus the TIE does not assume weak scattering; (ii) the TIE can give phase information at any distance from the specimen, not limited to a new field; (iii) information transfer in the TIE for each spatial frequency g will be multiplied by g2 and thus low frequency components will be dumped more with respect to high frequency components; (vi) the intensity derivative with respect to the direction of wave propagation is well approximated by using a set of three symmetric images; and (v) a substantially larger defocus distance than expected before can be used for high-resolution electron microscopy. In the second part of this report we applied the TIE down to atomic resolution images to obtain phase information and verified the following points experimentally: (i) although low frequency components are attenuated in the TIE, all frequencies will be recovered satisfactorily except the very low frequencies; and (ii) using a reconstructed phase and the measured image intensity we can correct effectively the defects of imaging, such as spherical aberrations as well as partial coherence.

Keywords: transfer of intensity equation; HREM; phase measurement; quantitative phase imaging; aberration correction.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
J Electron Microsc (Tokyo)Home page
M. Mitome, K. Ishizuka, and Y. Bando
Quantitativeness of phase measurement by transport of intensity equation
J. Electron Microsc. (Tokyo), September 19, 2009; (2009) dfp046v1.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.