Skip Navigation



Journal of Electron Microscopy Advance Access published online on May 8, 2008

Journal of Electron Microscopy, doi:10.1093/jmicro/dfn006
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
57/3/101    most recent
dfn006v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Yasunaga, T.
Right arrow Articles by Wakabayashi, T.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yasunaga, T.
Right arrow Articles by Wakabayashi, T.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2008. Published by Oxford University Press on behalf of Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oxfordjournals.org

Evaluation of a 2k CCD camera with an epitaxially grown CsI scintillator for recording energy-filtered electron cryo-micrographs

Takuo Yasunaga1,3* and Takeyuki Wakabayashi2

1 Department of Bioscience and Bioinformatics, Faculty of Computer Science and Systems Engineering, Kyushu Institute of Technology, Kawazu, Iizuka, Fukuoka, 820-8502, Japan
2 Department of Bioscience, School of Science and Engineering, Teikyo University, Toyosatodai, Utsunomiya, Tochigi, 302-8551, Japan
3 CREST, JST, Tokyo, Japan

* To whom correspondence should be addressed. Tel: +81-948-29-7826; Fax: +81-948-29-7801; E-mail: yasunaga{at}bio.kyutech.ac.jp

Zero-loss imaging of frozen-hydrated specimens requires a detector with high sensitivity, a low noise level and high spatial resolution, because more electrons are scattered inelastically than elastically by cryo-specimens and the number of electrons detected is ~1/4 of incident electrons after energy filtering. Cameras using charge-coupled devices (CCDs) are good candidates due to their high sensitivity. They have been used mainly to record electron diffraction patterns for electron crystallography due to their limited spatial resolution but recently used for acquiring direct images due to their convenience. The spatial resolution has been limited by the characteristics of a phosphor that is necessary to convert high-energy electrons to photons and the coupling. We adopted a CsI scintillator with good modulation transfer function (MTF), which was epitaxially grown from each of optical fibres. The stripes of carbon graphite with 3.4 Å spacing and 1.4 Å stripes of gold thin crystals could be recorded with a magnification of 240 000x and 560 000x at 200 kV, respectively. A computed Fourier transform of an image of a frozen-hydrated crystal of catalase containing about 1000 units showed diffraction spots at spatial frequencies of 1/9.6 Å–1 up to 1/8 Å–1 without background subtraction, when the image was recorded at 140 000x. These results show that the resolution of the developed camera was good enough to record images. Our used test method for MTF determination may be useful for others.

Keywords     CCD camera, epitaxially grown CsI, electron microscopy, catalase, energy-filtered imaging, modulation transfer function

Received     31 January 2007, accepted 26 March 2008


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.